Shim-pack G Series LC columns from Shimadzu offer the highest performance for both HPLC and UHPLC applications. The columns provide unique selectivities, inertness and reproducible separations. The G series is offered in four sub-groups: GIST, GISS, GIS and GWS series.

Shim-pack GIST Series Shim-pack GISS Series Shim-pack GIS Series Shim-pack GWS Series
Features Ultra-high inertness and high durability High-speed analysis with ultra-high inertness and high durability High retentivity, lower column back pressure, high inertness Medium retentivity and high inertness
Product Lineup C18, C8, Phenyl, NH2 C18 C18, CN C18
Particle Size 2, 3, 5 (NH2: 3, 5) 1.9, 3, 5 2, 3, 4, 5, 10 (CN: 3, 5) 5
pH Range 1-10 (Phenyl, NH2: 2-7.5) 1-10 2-7.5 2-7.5

Shim-pack GIST Series HPLC Columns

Shim-pack GIST series columns are packed with newly developed high-purity porous spherical silica. Superior inertness not only improves analytical precision, but also increases column durability. Shim-pack GIST series is capable of tolerating a wider pH (1-10) situation, making it suitable for analysis of many different compounds.C18, C8, Phenyl and NH2 columns are offered to cover an extended range of selectivity and meet diverse research and development needs.Furthermore, Shim-pack GIST series is designed with various particle size ranges, which make it easy to transfer your analysis from ultra-high-speed to conventional methods. The extremely unique phase characteristics of Shim-pack GIST Phenyl are critical to resolving compounds that cannot be separated using C18 or C8 columns. In addition to ϖ-ϖ interactions, Shim-pack GIST Phenyl provides hydrogen bonding secondary interactions, which results in retaining polar compounds at the same time. As the phenyl groups are directly bonded to the silica gel, Shim-pack GIST Phenyl is also capable of analysis of structural isomers due to its high stereo-selectivity.

Shim-pack GIST NH2 columns are highly suited for of analysis of Vitamin E or simultaneous of sugars that are hard to separate in reversed phase modes. Shim-pack GIST NH2 can analyze sugars with no separation of anomers, even under low temperature conditions. The columns deliver high reliability and stability for both qualitative and quantitative analyses.

Shim-pack GIST C18 Shim-pack GIST C8 Shim-pack GIST Phenyl Shim-pack GIST NH2
Bonded Phase Octadecyl Groups Octyl Group Phenyl Group Aminopropyl Group
Analysis Mode Reversed Phase Reversed Phase Reversed Phase HILIC mode, Normal Phase
Features Ultra-high inertness and high durability Ultra-high inertness and high durability Sugar analysis
Particle Size (μm) 2, 3, 5 2, 3, 5 2, 3, 5 3, 5
Pore Size (nm) 10 10 10 10
Surface Area (m2/g) 350 350 350 350
Carbon Loading (%) 14 8 10 7
End Cap 0 0 - -
Inertness -
pH Range 1-10 1-10 2-7.5 2-7.5

Shim-pack GISS Series HPLC Columns

High-speed analysis with ultra-high inertness and high durability

Shim-pack GISS series maintains the same ultra-high inertness and wider pH range as the Shim-pack GIST series while providing rapid separations with symmetric peaks. The optimization of surface area, pore size and chemical bonding delivers superior peak shapes, making these columns ideal for LC/MS/MS analysis.Shim-pack GISS series also includes the 1.9μm and 3μm HP series for UHPLC analyses.

Shim-pack GISS C18
Bonded Phase Octadecyl Groups
Analysis Mode Reversed Phase
Features High-speed analysis with ultra-high inertness and high durability
Particle Size (μm) 1.9, 3, 5
Pore Size (nm) 20
Surface Area (m2/g) 200
Carbon Loading (%) 9
End Cap 0
Inertness
pH Range 1-10

Shim-pack GIS Series HPLC Columns

High retentivity, lower column back pressure, high inertness

Shim-pack GIS series columns are packed with high purity silica gel and are your ideal generic HPLC columns. Highly uniform particles ensure stable mobile phase delivery and outstanding low pressure. The Shim-pack GIS series not only reduces your cost of solvents, but relieves your system load as well. A uniform silica surface and stable chemical modification ensure high analysis reproducibility.

Shim-pack GIS CN is capable of either normal phase or reversed phase analysis. Cyanopropyl groups bonded to silica gel with high density increases the difference recognition of hydrophilicity and the durability. Due to no end-capping, it is capable of analysis utilizing cyano group characteristics. In reversed phase mode, separation can be achieved for those compounds that could not be separated on straight-chain-alkyl columns, such as C18 or C8 bonded phases.

Shim-pack GIS C18 Shim-pack GIS CN
Bonded Phase Octadecyl Groups Cyanopropryl Group
Analysis Mode Reversed Phase Reversed Phase, Normal Phase
Features High retentivity, lower column back pressure, high inertness Suitable in either reversed phase or normal phase mode
Particle Size (μm) 2, 3, 4, 5, 10 3, 5
Pore Size (nm) 10 10
Surface Area (m2/g) 450 450
Carbon Loading (%) 15 14
End Cap 0 -
Inertness
pH Range 2-7.5 2-7.5

Shim-pack GWS Series HPLC Columns

Medium retentivity and high inertness

Shim-pack GWS series is an economical generic C18 column designed with high cost performance. A uniform pore size ensures low pressure. Complete end-capping makes it possible to be used for analysis of acidic or basic compounds. Shim-pack GWS series is the choice for cost control

Shim-pack GWS C18
Bonded Phase Octadecyl Groups
Analysis Mode Reversed Phase
Features Economical C18 column with medium retentivity and high inertness
Particle Size (μm) 5
Pore Size (nm) 10
Surface Area (m2/g) 450
Carbon Loading (%) 9.5
End Cap 0
Inertness
pH Range 2-7.5
Shim-pack G Series HPLC Columns